VRDLC3100 Displacer Liquid Level Transmitters (SIL2 Approval)
The transmitting head is Fisher FIELDVUE DLC3100 digital level
controller which is SIL2 certificated and imported from Emerson.
The torque tube and other parts are manufactured by V-RIVER locally.
Accuracy: ±0.2% for Level, ±0.5% for interface
Output signal: 4~20 mA, HART communication, (with two wires)
Operating pressure (MPa): 4.0, 6.3, 16.0, 20.0, and 32.0. or higher on request.
Medium temperature: -190℃ - +29℃ for Low-temp type;
-19℃ - +150℃ for normal type;
+150℃ - +350℃ for high-temp type;
+350℃ - +427℃ for ultra-high temp type
Ambient Temp: -40℃ - +80℃
Explosion proof: Ex d IICT6 and Ex ia IICT6
Enclosure protection grade: IP66
Differential density: 0.4 - 1.5g/cm3 (liquid level);
0.05 - 0.5g/cm3 (liquid interface)
Electrical connections: G1/2’’ and M20*1.5 adaptor available
Power supply: 12 to 30 V DC; 25mA
1.FISHER FIELDVUE DLC3100 Transmitting Heads are imported from FISHER EMERSON | |
| 2.Front view of FISHER FIELDVUE DLC3100 transmitting head |
| 3. Torque Tubes of FISHER FIELDVUE DLC3100 Transmitting Heads
|
| 4. NDT Test for Composition of the Torque Tube Is in Process |
| 5.The NDT Composition Test Report to an INCONEL Torque Tube Is Being Indicated |
| 6. Painted Parts of Displacer Liquid Level Transmitters |
| 7. Calibrating a FISHER FIELDVUE DLC3100 Transmitting Kit in our Workshop |
| 8. Calibrated FISHER FIELDVUE DLC3100 Transmitting Kits |
| 9. A Set of Completed Displacer Liquid Level Transmitter With FISHER FIELDVUE DLC3100 |
| 10. Completed VRDLC3100 Displacer Liquid Level Transmitters Are in the Packing |
| 11. The Packed VRDLC3100 Displacer Liquid Level Transmitters Are Being Shipped to the Customer |
DLC3100 Bulletin Version May 22, 2018.pdf